HORIZONTAL TERMINATIONS
HORIZONTAL VENT
HEAT SHIELD
CAUTION: This gas
appliance must not be
connected to or joined
with any other chimney
flue serving another
appliance.
HORIZONTAL VENT
HEAT SHIELD
90° ELBOW
NOTE: Horizontal sections require 1/4" (6
mm) rise for every 12" (305 mm) of travel.
VENTING
90° ELBOW
IMPORTANT: KOZY HEAT WALL THIMBLE PASS-THRU
(#800-WPT) MUST BE USED ON ALL HORIZONTAL VENT
RUNS USING 5" x 8" VENTING. FOLLOW INSTRUCTIONS ON
PAGE 22 OF THIS INSTALLATION MANUAL.
MAXIMUM HORIZONTAL VENTING
25 ft. (7.62 m) maximum, or 30 ft (9.14 m) maximum when
using stainless steel pipe for the entire length of termination.
MAXIMUM HORIZONTAL VENTING
6" (152 mm) VENT
PIPE SECTION
IMPORTANT:
HEAT SHIELD INCLUDED WITH THIS
FIREPLACE MUST BE INSTALLED
WHEN USING A 90-DEGREE ELBOW
DIRECTLY OFF THE TOP OF UNIT TO
HORIZONTALLY
VENT SYSTEM. THIS INCLUDES ANY
CORNER INSTALLATION
30 ft.*
(9.14 m)*
5" X 8"
PAGE 23
MINIMUM HORIZONTAL
VENTING
TERMINATION CAP
THE HORIZONTAL
POSITION
.
TERMINATION CAP
NOTE: Pages 27-28 have information
on restrictor installation in
conjunction with venting installation.
Page 49 has information on restrictor
recommendations depending on
burner flame appearance and
instructions on installation after
venting is completed.