5.0 OPTIONAL FAN INSTALLATION

5.1 #600-1 Optional Fan Kit

ATTENTION: Installation of this fan kit should be done only by a
qualified installer.
WARNING: Verify household breaker is shut off prior to working on
any electrical lines. Disconnect all electric power from fireplace before
performing any of these tasks.
WARNING - Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
Code approved line voltage wiring 14 gauge or better must be used
when wiring the optional #600-1 fan kit assembly. Refer to local codes
for specific requirements.
This optional fan kit includes:
(2) 110 CFM fan with temperature control switch and 4ft (1.22m)
fan cord
(4) 1/4" nuts
5.1.1 Fan Shield Installation
(2) fan shields are included in fireplace components packet.
These shields divert more air circulating through the fans upward,
increasing the volume exiting through the upper grill.
1.
Slide one corner of a fan shield onto the front chute on each fan,
making sure the 'V' portion of the shield is inside the chute.
2.
Slide fan shield down onto the chute.
Figure 5.1, Fan Shield Installation (1) shown
5.1.2 Fan Kit Installation
Fan wiring is on the next page.
1.
The lower grill must be removed from the fireplace prior to
installation of this fan.
Refer to Section 7.2 Grill Set Installation
and Removal on page 29.
2.
Insert fans through lower grill opening, push to back. Align
mounting slots in fan brackets onto mounting studs. Secure with
nuts.
3.
Connect fan wiring by attaching connectors on right fan onto
terminals on left fan.
4.
From inside lower right grill opening, loosen screws securing
removable access panel (with electrical box & romex connector
installed). Remove panel.
5.
Insert 110V - 120V wiring (with ground) through romex
connector and wire to the speed control / receptacle assembly,
matching black (hot), white (neutral), and green (ground) wires
22 OPTIONAL FAN INSTALLATION
FAN SHIELD
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
to corresponding wires on speed control / receptacle assembly.
6.
Secure speed control / receptacle assembly to the electrical box
with (2) screws provided.
7.
Re-install electrical access panel. Tighten screws.
8.
Attach temperature control switch to bottom of firebox.
9.
Plug cord into electrical box receptacle.
10. Turn speed control counter-clockwise until it 'clicks' . This is the
OFF position.
11. Turn speed control ON by turning knob clockwise past the 'click' -
this is the highest setting.
12. Re-install lower grill.
Refer to Section 7.2 Grill Set Installation and
Removal on page 29.
5.1.2.1 Temperature Control Switch Position
Before adjusting temperature control switch, unplug 3-prong plug
on fan cord from receptacle. Adjust position of temperature control
switch to a warmer location under firebox to turn fan ON sooner or
move it to a cooler location under firebox to turn fan ON later. Fan will
turn on when sensor in temperature control switch reaches
110° F and will turn OFF when sensor reaches 90° F. After adjustment,
plug 3-prong plug on fan cord into receptacle.