Min. / Max. Vertical Terminations (5" X 8") - kozy heat DASSEL DSL-36 Installation And Operation Manual

Direct vent dassel
Table of Contents

Advertisement

VERTICAL TERMINATIONS
MINIMUM VERTICAL VENTING
CAUTION: This gas appliance must not be
connected to or joined with any other chimney
flue serving another appliance.
NOTE: Horizontal Vent Heat
Shield is not used on vertical
venting configurations.
RESTRICTOR INSTALLATION
RECOMMENDED ON ALL VERTICAL TERMINATIONS OVER 6‟ (1.82 m).
REMOVE TAB TO CREATE
LARGE RESTRICTOR
SMALL RESTRICTOR
NOTE: Page 49 has information on restrictor
recommendations depending on burner flame
appearance and instructions on installation
after venting is completed.
VENTING
5" x 8"
4 FT
(1.22 m)
(Vertical)
MAXIMUM VERTICAL VENTING
TERMINATION CAP
SLIDE RESTRICTOR INTO EXHAUST PIPE ON TOP OF
FIREPLACE WITH TABS POINTING TOWARDS YOU
PRIOR TO ATTACHING VENTING.
PAGE 28
5" X 8"
40 FT
(12.19 m)
BEND TABS TO APPROX. 80
DEGREE ANGLES TO CREATE
TENSION TO HOLD ITSELF IN
PLACE WHEN INSTALLED.