CAUTION: If the burner and/or pilot have been burning, use the appropriate protection to avoid burns or
damage to personal property before removing any components.
1.
Turn gas control knob to the „OFF‟
position.
2.
Shut off gas supply at the manual
shut-off valve.
3.
Disconnect gas line flex tube from the
manual shut-off valve.
4.
Disconnect any wall switch, remote
control or thermostat wires from top &
bottom terminals on the gas valve.
5.
Remove upper hood, upper louver &
glass assembly. Refer to page 42 if
necessary.
6.
Remove logs and ember refractory
panels.
7.
Remove pilot shield.
8.
Remove the burner / burner heat shield
assembly from firebox by lifting up off
the orifice and out of firebox.
9.
Remove and save the (8) screws
securing the millivolt board to firebox
bottom.
10. Lift millivolt board up and out of
firebox being careful not to damage the
sealing gasket lying underneath.

MILLIVOLT BOARD REMOVAL

DISCONNECT ANY REMOTE /
THERMOSTAT WIRES
BURNER
PAGE 40
REMOVE PILOT SHIELD
BURNER HEAT SHIELD
REMOVE
(8) SCREWS
SECURING

MILLIVOLT BOARD.