Mantel Requirements - kozy heat DASSEL DSL-36 Installation And Operation Manual

Direct vent dassel
Table of Contents

Advertisement

22"
(559 mm)
WARNING:
NON-COMBUSTIBLE ZONE:
STAND-OFFS PROVIDE THE 10" (254 mm)
MINIMUM CLEARANCE TO HEADER. USE
ONLY NON-COMBUSTIBLE MATERIAL IN
THIS AREA FOR THE ENTIRE WIDTH OF
FIREPLACE. DO NOT USE WOOD,
SHEETROCK ETC. IN THIS ZONE.
REQUIRED STANDOFFS ARE NOT SHOWN FOR
CLARITY PURPOSES ONLY.
NOTE: OTHER CLEARANCES APPLY.
THESE CLEARANCES MUST BE
MAINTAINED.

MANTEL REQUIREMENTS

14"
(356 mm)
4" (102 mm)
14-1/2"
(368 mm)
10"
(254 mm)
14-1/2"
(368 mm)
HORIZONTAL VENT
HEAT SHIELD
PAGE 15
NON-COMBUSTIBLE ZONE:
NO COMBUSTIBLE MATERIALS
ALLOWED ON TOP OF FIREPLACE
WITHIN THE SHADED AREA FOR
THE ENTIRE WIDTH AND DEPTH
OF THE FIREPLACE WITH THE
EXCEPTION OF THE HEADER.
BACKSIDE OF HEADER MUST BE
NO MORE THAN 2-1/4" (57 mm)
FROM THE FRONT OF THE
FIREPLACE.
FIREPLACE
FRONT