Clearances - kozy heat DASSEL DSL-36 Installation And Operation Manual

Direct vent dassel
Table of Contents

Advertisement

STAND-OFF
FIREPLACE FRONT
LEFT SIDE
THERMOSTAT WIRE
GAS LINE HOLE
2-3/4"
70 mm
213 mm

CLEARANCES

Top of unit face to framing - 10" (254 mm)
From unit left & right sides & back - 1/4" (6 mm)
To flooring - 0" (0 mm)
Unit top to ceiling - 31" (787 mm)
Unit side to adjacent sidewall - 3" (76 mm)
Unit front to combustibles - 36" (914 mm)
Top of unit to 3/4" (19 mm) trim - 10" (254 mm)
Mantel must be a minimum of 14-1/2" (368 mm) above top of unit. The maximum mantel depth at this height is
4" (102 mm) deep. See additional mantel clearance configurations on page 15 of this installation manual.
SPECIFICATIONS
WARNING:
NON-COMBUSTIBLE ZONE:
STAND-OFFS PROVIDE THE
10" (254 mm) MINIMUM
CLEARANCE TO HEADER. USE
ONLY NON-COMBUSTIBLE
MATERIAL IN THIS AREA FOR
THE ENTIRE WIDTH OF
FIREPLACE. DO NOT USE
WOOD, SHEETROCK ETC. IN
THIS ZONE.
8-3/8"
PAGE 8
NOTE: OTHER CLEARANCES
APPLY. THESE CLEARANCES
MUST BE MAINTAINED.
REFER TO PAGE 15 FOR
MORE INFORMATION.
STAND-OFF
FIREPLACE FRONT
RIGHT SIDE
GAS LINE HOLE
ELECTRICAL
ACCESS
5-1/2"
140 mm
9-1/2"
241 mm