Optional Fan Installation - kozy heat Two Harbors 55616 Installation And Operation Manual

Table of Contents

Advertisement

OPTIONAL FAN INSTALLATION

INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD
AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
DO NOT CUT OR REMOVE GROUNDING PRONG FROM THIS PLUG.
IMPORTANT:
If installing fan, it is easier to complete prior to fireplace installation. Wiring must be done before enclosing fireplace sides. An electrical box
and romex connector are pre-installed on a removable panel on right side of fireplace. A receptacle / speed control assembly and (3) wire nuts
are included in fireplace components packet.
NOTE: Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer local electrical codes for specific requirements.
NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 Current Edition, or the Canadian electrical Code CSA C22.1.
NOTE: This fan will not operate unless speed control has been turned ON and sufficient heat has been applied to temperature control switch. The fan will
turn ON and OFF automatically as fireplace heats and cools. Adjust fan to desired speed while it is running.
The following components must be removed from fireplace prior to installation of this fan: Full door face, glass frame assembly, log set and
control board. Refer to corresponding pages in this installation manual for assistance if necessary.
1.
Insert fan through right side of lower grill opening, push to back wall.
2.
From inside lower right grill opening, loosen screw securing removable access panel (with electrical box & romex connector installed).
Remove panel.
3.
Insert 110V-120V wiring (with ground) through romex connector and wire to speed control / receptacle assembly matching black (hot),
white (neutral), and green (ground) wires to corresponding wires on speed control / receptacle assemblies. See illustration on following
page.
4.
Secure speed control / receptacle assembly to electrical box with (2) screws provided.
5.
Re-install electrical access panel. Tighten screw.
6.
Attach temperature control switch to bottom of firebox.
7.
Plug cord into electrical box receptacle.
8.
Turn speed control counter-clockwise until it „clicks‟. This is the OFF position.
9.
Turn speed control ON by turning knob clockwise past the „click‟ - this is the highest setting.
10. Re-install all previously removed components.
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting temperature control switch, unplug 3-prong plug
on fan cord from receptacle. Adjust position of temperature
control switch to a warmer location under firebox to turn fan
„ON‟ sooner or move it to a cooler location under firebox to turn
fan „ON‟ later. The fan will turn on when sensor in temperature
control switch reaches 110° F and will turn „OFF‟ when sensor
reaches 90° F. After adjustment, plug 3-prong plug on fan cord
into receptacle.
Figure 12a
PAGE 12

Advertisement

Table of Contents
loading