Minimum Horizontal Corner Installation - kozy heat DASSEL DSL-36 Installation And Operation Manual

Direct vent dassel
Table of Contents

Advertisement

HORIZONTAL TERMINATIONS
TYPICAL CORNER INSTALLATION 5" X 8"
90° elbow + 9" (229 mm) horizontal + termination cap. Horizontal Vent Heat Shield required.
HORIZONTAL TERMINATION CAP
9" PIPE
90° ELBOW
Shown without Horizontal
Vent Heat Shield for clarity
purposes only.
IMPORTANT: KOZY HEAT WALL THIMBLE PASS-THRU (#800-WPT) MUST BE USED ON ALL
HORIZONTAL VENT RUNS USING 5' x 8" VENTING. FOLLOW INSTRUCTIONS ON PAGE 22 OF THIS
INSTALLATION MANUAL.
CAUTION: This gas
appliance must not be
connected to or joined with
any other chimney flue
serving another appliance.
VENTING
VENTING DIMENSIONS FOR MINIMUM CORNER
INSTALLATIONS USING 5" x 8"
Vent Opening Dimensions: 12-1/2" (318 mm) H x 10-7/8" (276 mm)
From Floor or Hearth to Vent Opening Center: 37-7/8" (962 mm)
From Corner to Vent Opening Center: 15-7/8" (403 mm)
NOTE:
STAND-OFF HEAT SHIELD
NOT SHOWN FOR CLARITY
PURPOSES ONLY.
NOTE: Horizontal sections require 1/4" (6 mm)
rise for every 12" (305 mm) of travel.
PAGE 24
IMPORTANT:
THE HORIZONTAL
HEAT SHIELD INCLUDED WITH THIS
FIREPLACE MUST BE INSTALLED
WHEN USING A 90-DEGREE ELBOW
DIRECTLY OFF THE TOP OF UNIT TO
HORIZONTALLY
POSITION
VENT SYSTEM. THIS INCLUDES ANY
CORNER INSTALLATION
THE
.