Maintenance - kozy heat DASSEL DSL-36 Installation And Operation Manual

Direct vent dassel
Table of Contents

Advertisement

The appliance is required to be inspected at least once a year by a
professional service person.
The compartment below the firebox (behind the lower grill) must be
cleaned at least once a year, more frequent cleaning may be required
due to excessive lint from carpeting, bedding materials, or other
fibrous materials. It is imperative that the burner be cleaned once a
year.
NOTE: INSTALLATION AND REPAIR SHOULD BE
DONE ONLY BY QUALIFIED SERVICE PERSON.
THE APPLIANCE SHOULD BE INSPECTED
BEFORE USE AND ANNUALLY BY A QUALIFIED
SERVICE PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT
FROM CARPETING, BEDDING MATERIALS, ETC.
IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS AND CIRCULATION
AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT
CLEAN.
FAN
The fan should be disconnected from electrical current, and cleaned
(vacuumed) every six months. The bearings are sealed and require
no oiling.
VENT SYSTEM
Annual examination of the venting system by a qualified agency is
required.
IF THE VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR
ANY REASON, RE-INSTALL PER THE INSTRUCTIONS
PROVIDED WITH THE INITIAL INSTALLATION.
The flow of combustion and ventilation air must not be
obstructed.
IMPORTANT: ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE.
CAUTION: LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.

MAINTENANCE

Pilot
Burner Orifice
PAGE 50
MILLIVOLT BOARD SYSTEM
Annual cleaning of the burner system is
required.
The burner/heat shield assembly may be
removed for easier access. Refer to pages 40-
41 in this installation manual for complete
instruction on removing & reinstalling the
burner / heat shield assembly.
Visually check for blocked port holes,
especially near the pilot. Blocked port holes
may cause delayed ignition.
Reinstall the burner/heat shield assembly
following instructions on page 41of this
installation manual.
Visually check pilot light and burner when
in operation. The flames should be steady,
not lifting or floating.
GLASS CLEANING & REPLACEMENT
Clean glass only when cool and only with
non-abrasive cleansers.
Do not operate this fireplace with the glass/frame
assembly removed, cracked or broken.
The glass assembly, part #DSL-057T, shall only
be replaced as a complete unit, as supplied by
Hussong Mfg. Co., Inc.
Replacement of the glass & frame assembly,
part #DSL-057T, must only be performed by a
licensed or qualified service person.
DO NOT SUBSTITUTE MATERIALS.
Do not strike or slam glass door assembly.
CAUTION: KEEP THE APPLIANCE AREA
CLEAR OF COMBUSTIBLE MATERIALS,
SUCH AS GASOLINE AND OTHER
FLAMMABLE VAPORS AND LIQUIDS.
Burner Ports