OPTIONAL FAN INSTALLATION

INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
WARNING
THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND
SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE
GROUNDING PRONG FROM THIS PLUG.
If installing a fan, it is easier to complete prior to connecting millivolt board to gas supply. Wiring must be done before enclosing fireplace sides.
IMPORTANT
An electrical box and romex connector are pre-installed on a removable panel on right side of fireplace. A receptacle / speed control assembly and
(3) wire nuts are included in fireplace components packet.
Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly.
Refer local electrical codes for specific requirements.
This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the National
NOTE
Electrical Code, ANSI/NFPA 70 Current Edition, or the Canadian electrical Code CSA C22.1.
This fan will not operate unless speed control has been turned ON and sufficient heat has been applied to temperature control switch. The fan will
turn ON and OFF automatically as fireplace heats and cools. Adjust fan to desired speed while it is running.
Optional fan kit #WDM-028 includes: (2) 75 CFM fan with temperature control switch and 4ft. (1219mm) fan cord
1.
Remove upper hood, upper louver & lower grill, if installed. Page 24.
2.
Remove glass assembly. Page 12.
3.
Insert fans through lower grill opening on left side of gas valve. Push to back of fireplace. Align mounting slots in fan brackets with
mounting studs. Secure with nuts.
4.
From inside lower right grill opening, loosen screw securing removable access panel (with electrical box & romex connector installed).
Remove panel.
5.
Insert 115V wiring (with ground) through romex connector and wire to speed control / receptacle assembly matching black (hot), white
(neutral), and green (ground) wires to corresponding wires on speed control / receptacle assembly.
6.
Secure speed control / receptacle assembly to electrical box with (2) screws provided.
7.
Re-install electrical access panel. Tighten screw.
8.
Attach temperature control switch to bottom of firebox.
9.
Plug cord into electrical box receptacle.
10. Turn speed control counter-clockwise until it „clicks‟. This is the OFF position.
11. Turn speed control ON by turning knob clockwise past the „click‟ - this is the highest setting.
12. Re-install glass assembly, lower grill, upper louver & upper hood.
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting temperature control switch, unplug 3-prong plug
on fan cord from receptacle. Adjust position of temperature
control switch to a warmer location under firebox to turn fan ON
sooner or move it to a cooler location under firebox to turn fan
ON later. The fan will turn on when sensor in temperature control
switch reaches 110° F and will turn OFF when sensor reaches 90°
F. After adjustment, insert fan cord 3-prong plug into receptacle.
(4) 1/4" nuts
Temperature Switch
Electrical Box
Incoming wiring-
60Hz
110V-120V
Speed Control
Receptacle Assembly
Figure 13a