LIGHTING
1.
Set thermostat to the lowest setting, if installed.
2.
Turn off all electrical power to the appliance. (Fan).
3.
Open lower grill to access the gas valve & controls.
A. Push gas control knob in slightly and turn
clockwise to "OFF". Wait five (5) minutes to allow
any gas that may have accumulated inside the firebox
to escape. If you then smell gas, STOP! Follow the
safety information on the front cover and on page 44
of this installation manual. If you don‟t smell gas, go
to the next step.
NOTE: Gas control knob cannot be turned
from "PILOT" to "OFF" unless knob is pushed
in slightly. Do not force.
B. Locate pilot - follow metal tube from gas
control. The pilot is located inside the
combustion chamber.
C. Push gas control knob on the gas valve in
slightly and turn counterclockwise to „PILOT‟.
Push valve knob in and hold while
repeatedly pressing the piezo igniter button until
the pilot is lit while continuing to hold in the gas
control knob.
D. Hold gas control knob in for one (1) minute
after pilot is lit. Release the gas control knob. If
the pilot goes out, repeat steps C-D. If the pilot
refuses to stay lit, call your service technician or
the gas supplier. When the pilot is lit, proceed to
step E.
E. Push gas control knob in slightly and turn
counterclockwise to „ON‟. The burner can now
be turned „ON‟ by depressing the ON/OFF
rocker switch located beside the valve, or wall
switch, OR by setting the thermostat or remote
control to the desired setting.
F. Turn on all electric power to the appliance (if
applicable).
NOTE: When the fireplace is initially lit, condensation will appear on the glass; this is normal in all gas
fireplaces and will disappear after several minutes.
LIGHTING AND SHUTDOWN
A
B
C
D
E
PAGE 45
(cont.)
5 MINUTES
PILOT
PILOT TUBE
PIEZO BUTTON
1 MINUTE