OPTIONAL FAN INSTALLATION
INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND
SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE
GROUNDING PRONG FROM THIS PLUG.
IMPORTANT: If installing a fan, it is easier to complete prior to connecting millivolt board to gas supply. Wiring must be done before enclosing fireplace
sides. An electrical box and romex connector are pre-installed on a removable panel on right side of fireplace. A receptacle / speed control
assembly and (3) wire nuts are included in fireplace components packet.
NOTE: Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer local electrical codes for specific requirements.
NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 Current Edition, or the Canadian electrical Code CSA C22.1.
NOTE: This fan will not operate unless speed control has been turned „ON‟ and sufficient heat has been applied to temperature control switch. The fan will
turn „ON‟ and „OFF‟ automatically as fireplace heats and cools. Adjust fan to desired speed while it is running.
Optional fan kit #WDM-028 includes: (2) 75 CFM fan with temperature control switch and 4 ft. (1219 mm) fan cord
1.
Remove lower grill, if installed. Page 24.
2.
Remove glass assembly. Page
3.
Insert fans through lower grill opening on left side of gas valve. Push to back of fireplace, positioning as far apart as possible.
4.
From inside lower right grill opening, loosen screw securing removable access panel (with electrical box & romex connector installed).
Remove panel.
5.
Insert 115V wiring (with ground) through romex connector and wire to speed control / receptacle assembly matching black (hot), white
(neutral), and green (ground) wires to corresponding wires on speed control / receptacle assembly.
6.
Secure speed control / receptacle assembly to electrical box with (2) screws provided.
7.
Re-install electrical access panel. Tighten screw.
8.
Attach temperature control switch to bottom of firebox.
9.
Plug cord into electrical box receptacle.
10. Turn speed control counter-clockwise until it „clicks‟. This is the „OFF‟ position.
11. Turn speed control „ON‟ by turning knob clockwise past the „click‟ - this is the highest setting.
12. Re-install glass assembly and lower grill, .
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting temperature control switch, unplug 3-prong plug
on fan cord from receptacle. Adjust position of temperature
control switch to a warmer location under firebox to turn fan
„ON‟ sooner or move it to a cooler location under firebox to turn
fan „ON‟ later. The fan will turn on when sensor in temperature
control switch reaches 110° F and will turn „OFF‟ when sensor
reaches 90° F. After adjustment, plug 3-prong plug on fan cord
into receptacle.
12.
PAGE 13
Incoming wiring
Electrical Box
60Hz
110V-120V
Speed Control /Receptacle Assembly
Figure 13a
Temperature Switch:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Windom 56101

Table of Contents