Fan Installation (Optional) - kozy heat 55801 Duluth Installation & Operating Manual

Free-standing direct vent fireplace
Table of Contents

Advertisement

FAN INSTALLATION (OPTIONAL)

AN OPTIONAL FAN KIT, PART #DUL-028, IS AVAILABLE FOR THIS FIREPLACE AND MAY BE PURCHASED FROM YOUR DEALER.
INSTALLATION AND REPAIR OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER.
This optional fan kit includes:
- Right & left fan assemblies - mounted
- Temperature control switch with magnet attached
- Fan shield
NOTE: We recommend that a electrical outlet be installed near the location of the fireplace.
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged into a
properly grounded three-prong receptacle. Do not cut or remove the grounding prong from the plug.
Assembly & Installation
1. Attach the fan shield to the fan assembly by
aligning the holes in the shield to the holes in
the fan assembly and secure with the (3) hex
head screws, provided. Figure 7A.
Refer to Figure 7B for steps #2 - #4:
2. Locate the (4) mounting studs underneath the
fireplace (at the back).
3. Partially thread the (4) nuts (provided) onto
the mounting studs.
4. Place the fan assembly under the fireplace. Lift
the fan up and place the slots in the fan bracket
between the nuts and bottom side of the
fireplace.
5. Pull the upper flange on the fan shield slight
out, then up over the cast iron bottom (at the
back). Figure 7C. NOTE: This is a snug fit.
6. Secure fan in place by tightening the nuts.
Figure 7B.
- (4) Flange nuts
- (2) Phillips head screws (black)
- (3) Hex head screws (black)
Page 8
Figure 7A
Figure 7B
Figure
7C