FLAME APPEARANCE:
Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi
setting has been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. The flames will gradually turn yellowish-orange during the first 15 minutes of
operation. If the flames remain blue or the flames become dark orange with evidence of sooting (black tips), the burner tube
venturi may need to be adjusted.
WARNING: BURNER TUBE ADJUSTABLE VENTURI POSITIONING
SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL
SERVICE TECHNICIAN.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
1/16" (2 mm) OPEN
VENTURI POSITION
Closed too far
Open too far
NOTE: IF SOOT IS PRESENT, CHECK LOG POSITIONING BEFORE ADJUSTING
BURNER VENTURI. LOGS MUST NOT BLOCK BURNER PORTS.
IMPORTANT: SLIGHT ADJUSTMENTS TO THE BURNER VENTURI OPENING
CREATE DRAMATIC RESULTS. ADJUST AT SLIGHT INCREMENTS UNTIL DESIRED
LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR AT LEAST 15 MINUTES AND
ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS.
TO ADJUST VENTURI:
1.
Remove upper louver and hood. Refer to page 42.
2.
Remove glass frame assembly. Refer to page 16.
3.
Remove log set.
4.
Remove pilot shield.
5.
Remove burner / burner heat shield assembly.
6.
Loosen screw on burner venturi and adjust as necessary.
Tighten screw.
7.
Reinstall all components previously removed.
8.
Light fireplace and wait 15 minutes before determining if
any further adjustments are needed.

FINALIZING THE INSTALLATION

LP (PROPANE) GAS
1/2" (13 mm) OPEN
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
FLAME COLOR
Dark orange flame with black tips
Blue flames
VENTURI ADJUSTMENT
Open venturi setting slightly
Close venturi setting slightly
BURNER VENTURI
PAGE 48
WARNING: TO AVOID PROPERTY
DAMAGE OR PERSONAL INJURY,
ALLOW FIREPLACE AMPLE TIME
TO COOL BEFORE MAKING ANY
ADJUSTMENTS.