OPTIONAL FAN INSTALLATION (PRC-36 only)
INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY
ELECTRICAL LINES.
IMPORTANT: If installing a fan, it is easier to complete before the millivolt board is connected to the gas
line. Wiring must be done before enclosing fireplace sides. An electrical box and romex connector are pre-
installed on a removable panel on the right side of fireplace. A receptacle / speed control assembly and (3)
wire nuts are included in the fireplace components packet.
The optional fan kit #TRF-028 includes:
(2) 75 CFM fan with temperature control switch and 4 ft. (1219 mm) fan cord
NOTE: Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly.
Refer local electrical codes for specific requirements.
WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR
PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THIS PLUG.
110V - 120V
Incoming wiring
110V - 120V
60Hz
The following components must be removed from the fireplace prior to installation of this fan. Refer to the corresponding pages in this
installation manual for assistance if necessary.
.
A
Upper hood, upper louver & lower grill, if installed. Page 36.
B. Glass assembly. Page 15.
Electrical Box
Speed Control /
Receptacle Assembly
PAGE 16
Temperature Switch:
Magnetically attaches to bottom of
firebox.