INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD
AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
DO NOT CUT OR REMOVE GROUNDING PRONG FROM THIS PLUG.
IMPORTANT: If installing a fan, it is easier to complete before the control board is connected to the gas line.
NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 Current Edition, or the Canadian electrical Code CSA C22.1.
The following components must be removed from fireplace prior to installation of this fan. Refer to corresponding pages in this installation
manual for assistance if necessary: full door face, glass frame assembly.
1.
Insert fan through right side of lower grill opening , push to back wall.
2.
Remove electrical box / romex connector access screws (2) from fireplace right side wall. Insert 115V wiring (with ground) through
romex connector. Wire to receptacle/speed control assembly, reinstall electrical access panel.
3.
Place temperature control switch on bottom of firebox.
4.
Plug fan cord into electrical box receptacle.
5.
Turn speed control counter-clockwise until it „clicks‟. This is the OFF position. Turn speed control ON by turning knob clockwise past
the „click‟-this is the highest setting.
6.
Re-install glass frame assembly and full door face.
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting temperature control switch, unplug 3-prong plug
on fan cord from receptacle. Adjust position of temperature
control switch to a warmer location under firebox to turn fan
„ON‟ sooner or move it to a cooler location under firebox to turn
fan „ON‟ later. The fan will turn on when sensor in temperature
control switch reaches 110° F and will turn „OFF‟ when sensor
reaches 90° F. After adjustment, plug 3-prong plug on fan cord
into receptacle.
Ground (green) from receptacle
Access panel
Electrical box
Romex Connector
Incoming line 110-120V 60Hz
White (neutral) from incoming line
Figure 12b

OPTIONAL FAN INSTALLATION

Connect
Ground (bare) from incoming line
Connect
White (neutral) from receptacle
Figure 12a
Black from receptacle
Receptacle / Speed Control Assembly
Black from speed control
PAGE 12
Connect
White from speed control
Connect
Black (hot) from incoming line

Advertisement