Location Codes; Aix Location Codes - IBM E10 Service Manual

Enterprise storage server
Table of Contents

Advertisement

Locations
Locating an SSA Cable Loop Using Colored Labels . . . . . . . . . . . . . . . . . . . 36
Locating a CPI Cable Using Colored Labels. . . . . . . . . . . . . . . . . . . . . . 37
Primary Power Supply Location Codes, 2105 Model Exx/Fxx and Expansion Enclosure
Primary Power Supply Fan Locations, 2105 Model Exx/Fxx and Expansion Enclosure . . . . . . 40
390 V Battery Set Locations, 2105 Model Exx/Fxx and Expansion Enclosure
Rack, 2105 Model Exx/Fxx and Expansion Enclosure Storage Cage Power Supply Location Codes
2105 Model Exx/Fxx and Expansion Enclosure Storage Cage Fan (Top) Location Codes . . . . . 44
2105 Model Exx/Fxx and Expansion Enclosure Storage Cage Fan (Center) Location Codes . . . . 45
2105 Model Exx/Fxx and Expansion Enclosure Storage Cage Fan/Power Sense Card Location
Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2105 Model Exx/Fxx and Expansion Enclosure Storage Cage Power Planar Location Codes. . . . 47
2105 Model E10/E20 Electronics Cage Fan Location Codes. . . . . . . . . . . . . . . . 47
2105 Model E10/E20 Electronics Cage Power Supply Location Codes . . . . . . . . . . . . 48
2105 Model Exx/Fxx and Expansion Enclosure Electronics Cage Power Planar Location Codes
2105 Model E10/E20 Electronics Cage Sense Card Location Codes. . . . . . . . . . . . . 50
2105 Model E10/E20 Rack Power Control (RPC) Card Location Codes

Location Codes

The 2105 Model Exx/Fxx and Expansion Enclosure storage facility uses Physical Location Codes or AIX
Location Codes to provide mapping of the failing field replaceable units. The location codes are produced
by the system unit's firmware and AIX.
For quick access to the FRU location diagrams, find the FRU in the chapter table of contents on page ,
and go to the indicated page.
For a list of which FRU location codes are available in this chapter, see the chapter table of contents on
page .

AIX Location Codes

The basic formats of the AIX location codes are:
v For non-SCSI devices/drives
AB-CD-EF-GH
v For SCSI devices/drives
AB-CD-EF-G,H
For planars, cards, and non-SCSI devices the location code is defined as:
AB-CD-EF-GH
| | | |
| | | Device/FRU/Port ID
| | Connector ID
| devfunc Number, Adapter Number or Physical Location
Bus Type or PCI Parent Bus
v The AB value identifies a bus type or PCI parent bus as assigned by the firmware.
v The CD value identifies adapter number, adapter's devfunc number, or physical location. The devfunc
number is defined as the PCI device number times 8, plus the function number.
v The EF value identifies a connector.
v The GH value identifies a port, address, device, or FRU.
Adapters and cards are identified with just AB-CD.
The possible values for AB are:
00
Processor bus
01
ISA bus
2