IBM E10 Service Manual page 126

Enterprise storage server
Table of Contents

Advertisement

Codes
Table 11. Firmware Checkpoints. (continued)
Checkpoint
Description
E1EC
Get recovery image entry point
E1ED
Invalidate instruction cache
E1EE
Jump to composite image
E1EF
Erase flash
E1F0
Start O.B.E.
E1F1
Begin self-test sequence on boot device(s)
E1F2
Power on password prompt
E1F3
Privileged access password prompt
E1F5
Build boot device list.
E1F6
Determine boot device sequence.
E1F7
No boot image located.
E1FB
Scan SCSI bus for attached devices.
E1FD
Default Catch
E201
Setup PHB BARC addresses.
E202
Initialize PHB registers and PHB's PCI
configuration registers.
E203
Look for PCI to ISA bridge.
E204
Setup ISA bridge. PCI config. registers and
initialize
E206
Check for 50 MHz device on PCI Bus in Slots 1P
or 2P.
E207
Setup Data gather mode and 64/32-bit mode on
PCG.
E208
Assign bus number on PCG.
E209
Assign PCI I/O addresses on PCI.
E20A
Assign PCI I/O addresses on PCG
E20B
Check MCERs stuck at fault.
E20C
Testing L2 cache.
E211
IPL ROS CRC checking.
110
VOLUME 3, ESS Service Guide
Action/ Possible Failing FRU
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
A power on password should not be set. Call
the next level of support. The SP menus
options may need to be used to disable the
password.
A privileged access password should not be
set. Call the next level of support. The SP
menus options may need to be used to
disable the password.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
The operator panel will alternate between the
code E1FD and another Exxx code, where
Exxx is the point at which the error occurred.
If the Exxx is not listed in this table, go to
"MAP 4540: Cluster Minimum Configuration"
in chapter 3 of the Enterprise Storage Server
Service Guide, Volume 1.
I/O Planar See note 1 on page 100.
I/O Planar See note 1 on page 100.
I/O Planar See note 1 on page 100.
I/O Planar See note 1 on page 100.
1. I/O Planar
2. SSA cards in I/O planar slots 1P or 2P.
3. See note 1 on page 100.
I/O Planar See note 1 on page 100.
I/O Planar See note 1 on page 100.
I/O Planar See note 1 on page 100.
I/O Planar. See note 1 on page 100.
1. System Planar. See note 1 on page 100.
2. If the problem persists, go to "MAP 4540:
Cluster Minimum Configuration" in chapter
3 of the Enterprise Storage Server Service
Guide, Volume 1.
CPU card See note 1 on page 100.
I/O Planar. See note 1 on page 100.