Diagnostic Error Codes - IBM x Series 200 Hardware Maintenance Manual

Ibm computer drive hardware maintenance manual
Table of Contents

Advertisement

No Beep Symptom
No ac power
No beep and no video

Diagnostic error codes

Error Code/Symptom
001-XXX-000
(Failed core tests)
001-XXX-001
(Failed core tests)
001-250-000
(Failed System Board ECC)
001-250-001
(Failed System Board ECC)
005-XXX-000
(Failed Video test)
011-XXX-000
(Failed COM1 Serial Port test)
011-XXX-001
(Failed COM2 Serial Port test)
014-XXX-000
(Failed Parallel Port test)
015-XXX-001
(USB interface not found,
board damaged)
015-XXX-015
(Failed USB External
Loopback test)
1.
Check the power cord.
2.
Power supply.
1.
See "Undetermined problems" on page 100
Note: In the following error codes, if XXX is 000, 195, or 197,do not replace a FRU.
The description for these error codes are:
000
The test passed.
The Esc key was pressed to abort the test.
195
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
1.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
Video Adapter (if installed)
2.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
System Board
1.
Make sure parallel port is not disabled
2.
Re-run USB External Loopback test
3.
System Board
FRU/Action
FRU/Action
Symptom-to-FRU index
89

Advertisement

Table of Contents
loading

Table of Contents