Table 12. Service Request Numbers (continued)
Service
SRN
Request
Src.
Number
651-160
D
651-161
D
651-162
651-170
D
651-171
D
651-600
G
651-601
G
651-603
G
651-605
G
651-608
G
651-609
G
651-610
G
651-611
G
651-612
G
651-613
G
651-614
G
651-615
G
651-619
G
651-621 and
G
651-623
651-624
G
651-625
G
651-626
G
651-627
G
651-628
G
Failing
Description and Action
Function
Codes
2E0
Description: I/O planar sensor indicates a fan is turning too slowly.
Note: Go to "MAP 4740: Fan Check Detected by I/O Planar" in chapter 3
of the Enterprise Storage Server Service Guide, Volume 1.
152 2E2
Description: Sensor indicates a voltage is outside the normal range.
Description: See SRN 651-152
Description: Sensor status not available.
Action: Contact your next level of support.
Description: Sensor status not available
Action: Contact your next level of support.
Description: Uncorrectable memory or unsupported memory.
Action: Examine the memory modules and determine if they are supported
types. If the modules are supported, then replace the appropriate memory
module(s).
Description: Missing or bad memory
Action: If the installed memory matches the reported memory size, then
replace the memory: otherwise, add the missing memory.
2C6 2C7
Description: Bad or missing memory
2C6
Description: Failed memory module
Action: The most probable failure is the memory module paired with the
memory module identified by the location code.
D01
Description: Bad L2 Cache
D01
Description: Missing L2 Cache
210
Description: CPU internal error
210
Description: CPU internal cache error
D01
Description: L2 Cache parity or multi-bit ECC error
D01
Description: L2 cache ECC single-bit error
214
Description: Time-out error waiting for memory controller
292
Description: Time-out error waiting for I/O
Description: Problem log analysis indicates an error detected by the CPU.
The error log indicates the following physical FRU location(s) as the
probable cause(s).
Action: Use the physical location codes to replace the FRUs that are
identified on the problem detail screen.
2C6
Description: Correctable error threshold exceeded
214
Description: Memory controller internal error
214
Description: Memory Address (Bad address going to memory)
214
Description: Memory Data error (Bad data going to memory)
214
Description: Memory time-out error
210
Description: Processor time-out error
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9