IBM E10 Service Manual page 105

Enterprise storage server
Table of Contents

Advertisement

Table 6. Firmware Error Codes. (continued)
Error
Description
Code
40110000 Redundant power
supply failure.
40110001
Cluster Bay Power
(E10/E20)
Failure.
40110001
Cluster Bay Power
(F10/F20)
Failure.
40110002 Voltage not detected
on both CPU Cards.
40110003 Voltage not detected
on one CPU card.
Action/ Possible Failing FRU
See error code 40110001.
This information is for Model (E10/E20). See the next table entry for the Model
(F10/F20) information.
1. Ensure the electronics cage power supplies (above the cluster bay) are
switched on.
2. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the working cluster bay and use the Repair
Menu, Show / Repair Problems Needing Repair option.
3. Check power cable connections to the P2 connector on the I/O Planar.
4. Replace I/O Planar.
5. Service processor card.
6. A card plugged into the I/O Planar that is drawing too much current can
cause this error. One or more cards can be removed to see if the failure
goes away. See "MAP 4540: Cluster Minimum Configuration" in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
This information is for Model (F10/F20). See the previous table entry for the
Model (E10/E20) information.
1. Ensure the electronics cage power supplies (above the cluster bay) are
switched on (at the rear of the power supply).
2. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the working cluster bay and use the Repair
Menu, Show / Repair Problems Needing Repair option.
3. Replace I/O Planar.
4. A card plugged into the I/O Planar that is drawing too much current can
cause this error. One or more cards can be removed to see if the failure
goes away. See MAP 4540: Cluster Minimum Configuration in chapter 3 of
the Enterprise Storage Server Service Guide, Volume 1.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
1. Use the service terminal to display and repair any related power problems.
Connect the service terminal to the working cluster bay and use the Repair
Menu, Show / Repair Problems Needing Repair option.
2. Check the power bus is connected to the top of each CPU card (E10/E20
only).
3. Ensure all cluster bay power cables are properly plugged into the power
distribution planar, system planar.
Use the service terminal to display problem needing repair and then replace the
failing CPU Card. Connect the service terminal to the working cluster bay and
use the Repair Menu, Display / Repair Problems Needing Repair option. If the
cluster bay is not active, display the SP Problem log on the failing cluster and fix
any related problems. See "Appendix A. Service Processor Operation
Connection" on page 209.
Replace the failing CPU card.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
Codes
89