IBM E10 Service Manual page 132

Enterprise storage server
Table of Contents

Advertisement

Codes
Table 12. Service Request Numbers (continued)
Service
SRN
Request
Src.
Number
109-200
B
110-101
C
110–908
D
110-921 to
D
110-926
110-935
D
110-946
D
110-xxx
D
111-259
B
111-999
D
651-140
D
651-150
D
651-151
D
651-152
D
651-153
D
651-159
D
116
VOLUME 3, ESS Service Guide
Failing
Description and Action
Function
Codes
Description: The cluster bay crashed while running.
Action: Test the cluster bay. Connect the service terminal, use Main Service
Menu, then Machine Test Menu, then cluster bay. If no problem is found,
then call your next level of support.
Description: The diagnostics did not detect an installed resource.
Action: Call next level of support. For next level of support, run diag -a
command to list missing resource and then replace it.
Description: The diagnostics did not detect an installed resource.
Action: Call next level of support. For next level of support, run diag -a
command to list missing resource and then replace it.
xxx 812
Description: The cluster bay halted while diagnostics were executing.
Note: xxx corresponds to the last three digits of the SRN.
935 812
Description: The cluster bay halted while diagnostics were executing.
946 221
Description: The cluster bay halted while diagnostics were executing.
xxx 221
Description: The cluster bay halted while diagnostics were executing.
Note: xxx corresponds to the last three digits of the SRN. If your 110 SRN
is not listed below, use the 110-xxx procedure.
Description: Cannot display readable information on the terminal.
Action: Use "MAP 4020: SCSI Hard Drive Build" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
210
Description: Cluster Bay does not perform a soft reset.
165 221
Description: Operator panel display test failed
2E0
Description: I/O planar fan sensor indicates a fan has failed.
Note: Go to "MAP 4740: Fan Check Detected by I/O Planar" in chapter 3
of the Enterprise Storage Server Service Guide, Volume 1.
152 2E2
Description: Sensor indicates a voltage is outside the normal range.
Note: The FRUs and Notes for Failing Function Code 152 will have you
display and repair any other related problem logs, see "Failing Function
Codes" on page 131.
2E1
Description: Sensor indicates an abnormally high internal temperature.
Action: Verify that:
1. The room ambient temperature is within the cluster bay operating
environment.
2. There is unrestricted air flow around the cluster bay.
3. There are no fan failures.
Use the service terminal to show and repair any related problems.
If none of these problems exist, replace the FRU.
152 2279
Description: Sensor indicates a power supply has failed.
Description: Sensor indicates a FRU has failed.
Action: Instead of using a failing function code, use the physical location
code or codes to replace the FRU or FRUs that are identified on the
problem report screen.