IBM E10 Service Manual page 120

Enterprise storage server
Table of Contents

Advertisement

Codes
Table 10. SP Checkpoints. (continued)
Checkpoint
Description
E241
Reset PCI bus
E242
Initialize ISA DMA channel
E243
Setup grackle configuration registers
E244
Enable system speaker and send a beep!
E246
System firmware corrupted, take recover
path
E247
Capture DIMM SPDs into NVRAM
E249
Enter recover paths main code
E24C
L2 cache array test fails, system hangs
E24D
L2 cache array test fails, system hangs
E297
Start firmware softload path execution
E298
Start firmware recovery path execution
E299
Start C code execution
E600
SSA PCI adapter open firmware has run
successfully
E601
SSA PCI adapter BIST has been started but
failed to complete after four seconds
E602
SSA PCI adapter open firmware has started
E603
SSA PCI adapter BIST has completed with
an error
E604
SSA PCI adapter BIST and following POSTs
have completed successfully
E605
SSA PCI adapter BIST has completed
successfully, the following POSTs have failed
E60E
SSA PCI adapter open firmware about to
exit (no stack corruption)
E60F
SSA PCI adapter open firmware has run
unsuccessfully
E6FF
SSA PCI adapter open firmware about to
exit (with stack corruption)
F0FF
Service processor firmware fail
OK
SP Ready Waiting for Power-On
READY
SP Cluster Bay may be powered off if
CD-ROM tray does not open when the eject
button is pressed
STBY
SP Ready, system was shutdown by the
operating system and is still powered on
104
VOLUME 3, ESS Service Guide
Action/ Possible Failing FRU
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
I/O Planar, see 1 on page 100
See 1 on page 100
See 1 on page 100
See 1 on page 100
SSA card, identify the adapter by using "MAP
4540: Cluster Minimum Configuration" in
chapter 3 of the Enterprise Storage Server
Service Guide, Volume 1 to isolate the failing
SSA card
See Action/Possible Failing FRU with
Checkpoint E600
See Action/Possible Failing FRU with
Checkpoint E600
See Action/Possible Failing FRU with
Checkpoint E600
See Action/Possible Failing FRU with
Checkpoint E600
See Action/Possible Failing FRU with
Checkpoint E600
See Action/Possible Failing FRU with
Checkpoint E600
See Action/Possible Failing FRU with
Checkpoint E600
See Action/Possible Failing FRU with
Checkpoint E600
See "Firmware/POST Error Codes" on
page 73 for 4BA10004
None, Normal operation
None, Normal operation
This condition can be requested by a
privileged system user with no faults. See SP
error log for possible operating system fault
indications.

Advertisement

Table of Contents
loading

This manual is also suitable for:

F10F20E202105 e102105 f102105 f20 ... Show all