Cluster Bay Connectors For Service Terminal (S008027M) - IBM E10 Service Manual

Enterprise storage server
Table of Contents

Advertisement

Service Processor Connection
b. Quiesce the cluster bay you are servicing by selecting the following options from the Main
Service Menu, see "Utility Menu" on page 67:
Utility Menu
Resource Management Menu
Quiesce a Resource
Quiesce the cluster bay you are servicing.
c. Power Off the cluster bay you are servicing by selecting the following options from the Main
Service Menu:
Utility Menu
Cluster Bay Power Off/On
Select Power Off Cluster Bay 1 or 2
d. Wait three minutes for the cluster bay to power off. When OK is displayed on the cluster bay
operator panel, go to step 7.
7. Connect the service terminal to the cluster bay being serviced:
a. Connect the service terminal interface cable to the serial port connector (9 pin) on the service
terminal.
b. Connect the other end of the cable to the S2 connector on the cluster bay being serviced, cluster
bay 1 or cluster bay 2.
Note: The service terminal interface cable is stored in the 2105 Model E10/E20 rack or connected
to S2 on the front of cluster bay 1 or 2.
Figure 90. Cluster Bay Connectors for Service Terminal (S008027m)
8. Logically connect the service terminal to the cluster bay:
v OS/2 Operating System:
a. At the EBTERM window, select and click on the Connect menu option.
b. At the Connect dialog box, click on 2105 Direct Connect.
c. Go to step 9 on page 211.
v Windows Operating System:
a. At the NetTerm window, single click on File and then Phone Directory
b. At the Phone Directory, click on IBM 2105 VSS/ESS (Direct Connect, IBM3151 emulation),
and then click on Connect.
c. Go to step 9 on page 211.
210