IBM E10 Service Manual page 125

Enterprise storage server
Table of Contents

Advertisement

Table 11. Firmware Checkpoints. (continued)
Checkpoint
Description
E1BE
Create op-panel node.
E1BF
Create pwr-mgmt node.
E1C0
Create ISA ethernet node.
E1C5
Create ISA interrupt controller (pic) node.
E1C6
Create dma node.
E1D0
Create PCI SCSI node.
E1D3
Create (* wildcard *) SCSI block device node
(SD).
E1D4
Create (* wildcard *) SCSI byte device node (ST). See note 1 on page 100.
E1DB
Create floppy controller (FDC) node.
E1DC
Dynamic console selection.
E1DD
Early processor exception
E1DE
Alternating pattern of E1DE and E1AD is used to
indicate a Default Catch condition before the
firmware "checkpoint" word is available.
E1DF
Create diskette drive (disk) node
E1E0
Program flash
E1E1
Flash update complete
E1E2
Initialize System I/O
E1E3
PReP boot image initialization.
E1E4
Initialize Super I/O with default values.
E1E5
XCOFF boot image initialization.
E1E6
Set up early memory allocation heap.
E1E7
PE boot image initialization.
E1E8
Initialize primary diskette drive (polled mode).
E1E9
ELF boot image initialization.
E1EA
Firmware flash corrupted.
E1EB
Verify flash EPROM recovery image in LIC library
on SCSI hard drive.
Action/ Possible Failing FRU
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
The S1 port is defined as the system console
port even though no system console is ever
attached to the cluster bay. Simulate replacing
the I/O planar battery, go to "MAP 4700:
Cluster Bay FRU Replacement" in chapter 3
of the Enterprise Storage Server Service
Guide, Volume 1. Do the included procedure
to define the S1 port. If the cluster bay still
hangs with E1DC, replace the I/O planar
using the same MAP.
I/O Planar (See notes on 72.)
See note 1 on page 100.
1. I/O Planar (See notes on 72.)
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
See note 1 on page 100.
Call the next level of support. (In a standard
RS/6000 a flash recovery diskette would be
used for recovery.)
Replace the I/O planar.
Call the next level of support. (In a standard
RS/6000 a flash recovery diskette would be
used for recovery.)
See note 1 on page 100.
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
Codes
109

Advertisement

Table of Contents
loading

This manual is also suitable for:

F10F20E202105 e102105 f102105 f20 ... Show all

Table of Contents