Service Processor Operations - IBM E10 Service Manual

Enterprise storage server
Table of Contents

Advertisement

9. If the operation is successful, the SP Main Menu will be displayed.
For a listing of all service processor menus, go to "Service Processor Operations".
10. Verify that the cluster bay being serviced is powered on by pressing the eject button on it's CD-ROM
drive.
Did the CD-ROM disk tray come out?
v Yes, the cluster bay is powered on go to "MAP 4360: Cluster Operator Panel Codes" in chapter 3
of the Enterprise Storage Server Service Guide, Volume 1.
v No, the cluster bay is not powered on go to step 11.
11. Attach the service terminal interface cable to the cluster bay you are NOT servicing and start the
service login operation, see "Service Login Operation Connection, with Cluster IML Complete" on
page 57.
Power On the cluster bay you are servicing by selecting the following options from the Main Service
Menu:
Utility Menu
Cluster Bay Power Off/On
Select Power On Cluster Bay 1 or 2
12. Wait about 30 seconds, then press the eject button on the CD-ROM drive in the cluster bay being
serviced.
Did the CD-ROM disk tray come out?
v Yes, the cluster bay is powered on. Leave the service terminal attached to the cluster bay you are
NOT servicing, go to step 6b on page 210.
v No, the cluster bay is not powered on go to "MAP 4360: Cluster Operator Panel Codes" in chapter
3 of the Enterprise Storage Server Service Guide, Volume 1.

Service Processor Operations

The following diagram is an overview of the six options available on the cluster bay service processor
main menu and the options that are available with each of them.
For instructions on connecting and activating the service terminal, see "Service Terminal Setup and 2105
Configuration Verification" on page 54.
Service Processor Connection
Appendix A. Service Processor Connection
211