IBM E10 Service Manual page 92

Enterprise storage server
Table of Contents

Advertisement

Codes
Table 6. Firmware Error Codes. (continued)
Error
Description
Code
25010002 Diskette in drive does
not contain an *.IMG
file.
25010003 Cannot open
OPENPROM package.
25010004 Cannot find
OPENPROM node.
25010006 System id does not
match image system
id.
25010007 Image has bad CRC.
25010008 Flash is write
protected, update
cancelled.
25010009 Flash module is
unsupported or not
recognized.
2501000A Flash write protected.
25A0xxx0 L2 Cache controller
problem.
25A0xxx1 L2 Cache controller
problem.
25A1xxx1
L2 SRAM failure
to
25A1xxxB
76
VOLUME 3, ESS Service Guide
Action/ Possible Failing FRU
Insert diskette with firmware update file.
Replace I/O Planar.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Replace I/O Planar.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Call next level of support.
Replace the diskette. Call next level of support.
1. To retry, power the cluster bay off and on. Connect the service terminal to
the working cluster bay and use the Alternate Cluster Repair Menu options to
quiesce, power off, power on and resume the failing cluster bay.
2. Replace I/O Planar.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Make sure the correct firmware update diskette is being used.
1. Power off and on the cluster bay. Connect the service terminal to the working
cluster bay and use the Alternate Cluster Repair Menu options to quiesce,
power off, power on and resume the failing cluster bay.
2. Replace I/O Planar.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
1. Remove the CPU card in P1–C2 (farthest away from the memory cards). If
the problem is resolved, replace the removed CPU card. If not, continue.
2. Exchange the CPU card in P1–C1 (closest to the memory cards) with the
CPU card removed in step one. If the problem is resolved, replace the
removed CPU card. If not, continue.
3. Return both CPU cards to their original slots.
4. Replace the system planar.
Note: Go to "MAP 4700: Cluster Bay FRU Replacement" in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
See error code 2B2xxx22 for xxx definitions.
See 25A0xxx0 action.
See error code 2B2xxx22 for xxx definitions.
1. Remove the CPU card in P1–C2 (farthest away from the memory cards). If
the problem is resolved, replace the removed CPU card. If not, continue.
2. Exchange the CPU card in P1–C1 (closest to the memory cards) with the
CPU card removed in step one. If the problem is resolved, replace the
removed CPU card. If not, continue.
3. Return both CPU cards to their original slots.
See error code 2B2xxx22 for xxx definitions.