Codes
Table 12. Service Request Numbers (continued)
Service
SRN
Request
Src.
Number
805-609
G
805-610
G
805-611
G
805-612
G
805-616
G
805-617
G
805-618
G
805-619
G
805-621
G
805-622
G
805-623
G
805-624
G
805-625
G
805-631
G
805-632
G
805-633
G
805-634
G
805-635
G
124
VOLUME 3, ESS Service Guide
Failing
Description and Action
Function
Codes
D01
Description: Problem log analysis indicates a machine check due to a L2
parity error.
227
Description: Problem log analysis indicates a machine check due to ISA
device error, but the device could not be identified.
227
Description: Problem log analysis indicates a machine check due to
EISA/ISA bus time out error, but the device could not be identified.
214
Description: Problem log analysis indicates a machine check due to an
Illegal L2 copy-back operation.
software
Description: Problem log analysis indicates a machine check due to
software.
Description: Problem log analysis indicates a machine check of unknown
origin.
Action: If the problem is persistent, use "MAP 4540: Cluster Minimum
Configuration" in chapter 3 of the Enterprise Storage Server Service Guide,
Volume 1.
Description: Problem log analysis indicates multiple instances of machine
check of unknown origin.
Action: If the problem is persistent, use "MAP 4540: Cluster Minimum
Configuration" in chapter 3 of the Enterprise Storage Server Service Guide,
Volume 1.
221
Description: Problem log analysis indicates a machine check due to an
unidentified source on the I/O subsystem.
292
Description: Problem log analysis indicates a machine check due to
Integrated PCI device does not respond.
293
Description: Problem log analysis indicates a machine check due to
Integrated PCI device does not respond.
294
Description: Problem log analysis indicates a machine check due to
Integrated PCI device does not respond.
295
Description: Problem log analysis indicates a machine check due to
Integrated PCI device does not respond.
868
Description: Problem log analysis indicates a machine check due to
Integrated PCI device does not respond.
292
Description: Problem log analysis indicates a machine check due to
Internal error from PCI device.
293
Description: Problem log analysis indicates a machine check due to
Internal error from PCI device.
294
Description: Problem log analysis indicates a machine check due to
Internal error from PCI device.
295
Description: Problem log analysis indicates a machine check due to
Internal error from PCI device.
868
Description: Problem log analysis indicates a machine check due to
Internal error from PCI device.

Advertisement