Fibre Channel Exception Symptom Codes - IBM E10 Service Manual

Enterprise storage server
Table of Contents

Advertisement

ESC
Description of ESC
3111
CE request to power off cluster bay
3112
CE request to reset service mode for cluster bay
3113
Cluster Bay failover
3114
Cluster Bay fenced due to excessive failover/failback
3115
Cluster Bay failback
3116
Cluster Bay failback from cluster bay failover
3117
Cluster Bay failover Without failback

Fibre Channel Exception Symptom Codes

The following Fibre Channel code values are set during analysis. The allocated ESC range for Fibre
Channel errors is '3200'x to '32FF'x.
ESC
Description of ESC
3200
Fibre Channel heartbeat failure for adapter in service
3201
Fibre Channel adapter heartbeat failure
3202
Fibre Channel adapter time-out
3203
Fibre Channel adapter invalid response
3204
Fibre Channel adapter failure response
3205
IOCTL requested fence of Fibre Channel adapter
3206
Fibre Channel adapter not available
3207
Fibre Channel adapter Error: no data while in service mode
3208
Fibre Channel adapter Error: no data - temporary
3209
Fibre Channel adapter Error: no data - permanent
3210
Fibre Channel adapter Error: invalid data while in service mode
3211
Fibre Channel adapter Error: invalid data - temporary
3212
Fibre Channel adapter Error: invalid data - permanent
3221
Fibre Channel adapter Error: configuration failure - temporary
3222
Fibre Channel adapter Error: configuration failure - permanent
3225
Fibre Channel adapter Error: panic - temporary
3226
Fibre Channel adapter Error: panic - permanent
3227
Fibre Channel adapter Error: 603 hardware check - temporary
3228
Fibre Channel adapter Error: 603 hardware check - permanent
3265
Fibre Channel adapter Error: fence logical path - temporary
3269
Fibre Channel adapter Error: link incident - temporary
326A
Fibre Channel adapter Error: link incident, bit error rate exceeded - permanent
326B
Fibre Channel adapter Error: link incident - informational message
3270
Fibre Channel adapter Error: configuration single flash failure - temporary
3271
Fibre Channel adapter Error: configuration single flash failure - permanent
3272
Fibre Channel adapter Error: configuration both flash failure - temporary
3273
Fibre Channel adapter Error: configuration both flash failure - permanent
3274
Fibre Channel adapter Error: configuration checksum failure - temporary
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
2105 Exception Symptom Codes
157

Advertisement

Table of Contents
loading

This manual is also suitable for:

F10F20E202105 e102105 f102105 f20 ... Show all

Table of Contents