Switching the Operating Mode
Switching between Displays in the Mode Selection Menu
r u n
1 2 3 4
5 6
V A Yrs
s e t
t s t
p r t
i n i
(If the
Key is pressed, the S8AS will return to the RUN display.)
When the S8AS is switched to the Mode Selection Menu from Run Mode, the
seven-segment display will show "RUN."
°C
s
If the
Key is pressed, SET will be displayed. If the
this point, the S8AS will enter Setting Mode.
Refer to 4-4 Switching to Setting Mode to 4-7 Special Settings and Communi-
cations Settings.
Note This option will not be displayed for models that do not permit changes
in parameter settings (S8AS-24006/48008N).
If the
Key is pressed, TST will be displayed. If the
this point, the S8AS will enter Test Mode.
Refer to SECTION 5 Trial Operation to Actual Operation.
Note If the protection level is set to level 2, this option will not be displayed
for any models.
If the
Key is pressed, PRT (protect) will be displayed.
If the
Key is pressed at this point, the S8AS will switch to the protection
level display.
Refer to 4-3 Changing the Protection Level for details on setting parameters.
Note This option will not be displayed for models that do not permit change
in parameter settings (S8AS-24006N/48008N).
If the protection level is set to level 0, INI will be displayed when the
pressed.
If the
Key is pressed at this point, the S8AS will switch to the parameter
initialization display.
Note
1. This option will not be displayed for models that do not permit change in pa-
rameter settings (S8AS-24006N/48008N).
2. The default protection level is level 1. At this level, the INI option will not be
displayed for any models.
Section 4-2
Key is pressed at
Key is pressed at
Key is
57

Hide quick links: