Frame Structure
Missing FINS-mini
Incomplete MRC and SRC Codes in FINS-mini
Incomplete Node Address
Missing Subaddress, Invalid BCC
Command
Node No. Subaddress
0
1
0
STX
Response
Node No. Subaddress
0
1
0
STX
The end code is 14 (format error).
Command
Node No. Subaddress
0
1
0
STX
The SRC is missing one character.
Response
Node No. Subaddress
0
1
0
STX
The end code is 14 (format error).
Command
BCC
ETX
STX
The node address is missing one character.
Response
None (There is no response because the return node address is unknown.)
Command
Node No.
ETX
0
1
STX
Response
Node No. Subaddress
0
1
0
STX
The subaddress is 00 and the end code is 13 (BCC error).
SID
BCC
0
0
ETX
End code
BCC
0
1
4
ETX
SID
FINS-mini
MRC
0
0
End code
BCC
ETX
0
1
4
BCC
Err
End code
BCC
0
1
3
ETX
Section 6-2
BCC
0
ETX
93