Glossary
Seven-segment Display
Symbol
Seven-segment
as
AS
bit
BIT
bps
BPS
c-t
C-T
c-v
C-V
dws
DWS
ege
EGE
ful
FUL
hlf
HLF
ini
INI
ins
INS
len
LEN
lfe
LFE
lng
LNG
lvl
LVL
prt
PRT
pty
PTY
rst
RST
display
When the power supply is turned ON, this display is shown for
approximately 3 s during the initialization process. When initializa-
tion has finished, the display will change automatically.
BIT is an abbreviation for "stop bits."
Sets the number of stop bits for RS-485 communications.
Sets the baud rate for RS-485 communications.
C-T is an abbreviation for "cut off type."
The abnormal current tripping type can be selected from Standard
(USU), Instantaneous (INS), or Extended (LNG)
C-V is an abbreviation for "cutoff value."
Sets the abnormal current tripping threshold. Setting range: 0.5 to
3.8 A.
DWS is an abbreviation for "shutdown sequence."
Sets the shutdown sequence time for each branch output. Setting
range: 0.0 to 99.9s.
EGE is an abbreviation for "edge."
It is one of the branch output tripping methods using the external
tripping input (TRG). All branch outputs are cut off according to the
shutdown sequence when the input is turned ON.
FUL is an abbreviation for "full."
It is displayed when the remaining lifetime of the maintenance fore-
cast monitor is more than 10 years.
HLF is an abbreviation for "half."
It is displayed when the remaining lifetime of the maintenance fore-
cast monitor is more than 5 years.
INI is an abbreviation for "initial."
It is an option in the Mode Selection Menu and is displayed when
the protection level is 0. If the ENT Key is pressed, all S8AS
parameters will return to default values.
INS is an abbreviation for "instantaneous."
It represents instantaneous detection. It is the abnormal current
cutoff type that trips within 20 ms.
LEN is an abbreviation for "length."
Sets the data length for RS-485 communications.
LFE is an abbreviation for "life."
Sets the number of years for the maintenance forecast monitor
function to output an alarm. (0.5 to 5.0 years.)
LNG is an abbreviation for "date long."
It represents extended detection. It is the abnormal current cut off
type that trips within 1,000 ms.
LVL is an abbreviation for "level."
It is one of the branch output tripping methods using the external
tripping input (TRG). All branch outputs are cut off according to the
shutdown sequence when the input is turned ON or turned OFF.
PRT is an abbreviation of "protect."
It is an option in the Mode Selection Menu that must be selected to
change the protection level.
PTY is an abbreviation for "parity bit."
Sets the parity for RS-485 communications.
RST is an abbreviation of "reset."
Press the Reset Key after an abnormal tripping event. The RST
indicator will flash while the error is cleared.
Meaning
Appendix A
Page
8
73
71
62
60, 61
67
40, 69
34
34
57
62
72
64
62
40, 69
57, 59
74
76
119