Component Names and Functions
°C
Lit when displaying the temperature.
s
Lit when setting the startup sequence time or shutdown
sequence time.
(11) Status indicators (Green/Red)
Indicate the connection and cut off status for the branch outputs.
• Six-branch Output Model
1
2
3
4
5
6
Not lit
Green
Lit
Flash
Red
Lit
Flash
(12) Operation Keys
Reset (RST) Key
Used to clear the error status when a branch output was cut
off by an error or there was an alarm output.
RST
Enter (ENT) Key
Used to switch the display item, enter or execute settings, etc.
Up (SEL) Key
Used to change the display item forward or to increase a set
value.
Down (CH) Key
Used to switch the branch output or to decrease a set value.
The branch output number that is set remains the same in
other modes.
(13) Communications Terminals (A (−), B (+)) (Only for Models That
Support Communications)
Used to connect to the RS-485 communications line.
A (−) B (+)
Not
Set to OFF (disconnected) or forcibly
connected
cut off by command.
Connected
Connected normally.
Not con-
In the startup sequence and waiting for
nected
connection.
Cut off
Cut off due to an error.
Cut off
Cut off by an internal error.