Table 80 Relationship between the configuration and display of the system clock
System clock displayed by the display clock
Configuration
command
1 and 3
If date-time is not in the summer time range,
date-time is displayed.
If date-time is in the summer time range,
"date-time" + "summer-offset" is displayed.
[1], 3 and 1
If date-time is not in the summer time range,
date-time is displayed.
date-time is in the summer time range:
If the value of "date-time" - "summer-offset" is not
in the summer-time range, "date-time" -
"summer-offset" is displayed;
If the value of "date-time" - "summer-offset" is in the
summer-time range, date-time is displayed.
2 and 3 or
If the value of the original system clock ÐǬ±
3 and 2
"zone-offset" is not in the summer-time range, the
original system clock ÐǬ± "zone-offset" is
displayed.
If the value of the original system clock ÐǬ±
"zone-offset" is in the summer-time range, the
original system clock ÐǬ± "zone-offset" +
"summer-offset" is displayed.
1, 2 and 3 or
If the value of "date-time"ÐǬ±"zone-offset" is not
1, 3 and 2
in the summer-time range,
"date-time"ÐǬ±"zone-offset" is displayed.
If the value of "date-time"ÐǬ±"zone-offset" is in
the summer-time range,
"date-time"ÐǬ±"zone-offset"+"summer-offset" is
displayed.
[1], 2, 3 and 1 or
If date-time is not in the summer time range,
[1], 3, 2 and 1
date-time is displayed.
date-time is in the summer time range:
If the value of "date-time"-"summer-offset" is not in
the summer-time range,
"date-time"-"summer-offset" is displayed;
If the value of "date-time"-"summer-offset" is in the
summer-time range, date-time is displayed.
Configuring a Banner
Introduction to banners
Banners are prompt information displayed by the system when users are
connected to the device, perform login authentication, and start interactive
configuration. The administrator can set corresponding banners as needed.
Example
Configure: clock datetime 1:00 2007/1/1 and clock
summer-time ss one-off 1:00 2006/1/1 1:00 2006/8/8 2
Display: 01:00:00 UTC Mon 01/01/2007
Configure: clock datetime 8:00 2007/1/1 and clock
summer-time ss one-off 1:00 2007/1/1 1:00 2007/8/8 2
Display: 10:00:00 ss Mon 01/01/2007
Configure: clock summer-time ss one-off 1:00 2007/1/1
1:00 2007/8/8 2 and clock datetime 1:00 2008/1/1
Display: 01:00:00 UTC Tue 01/01/2008
Configure: clock summer-time ss one-off 1:00 2007/1/1
1:00 2007/8/8 2 and clock datetime 1:30 2007/1/1
Display: 23:30:00 UTC Sun 12/31/2006
Configure: clock summer-time ss one-off 1:00 2007/1/1
1:00 2007/8/8 2 and clock datetime 3:00 2007/1/1
Display: 03:00:00 ss Mon 01/01/2007
Configure: clock timezone zone-time add 1 and clock
summer-time ss one-off 1:00 2007/1/1 1:00 2007/8/8 2
Display: 02:00:00 zone-time Sat 01/01/2005
Configure: clock timezone zone-time add 1 and clock
summer-time ss one-off 1:00 2005/1/1 1:00 2005/8/8 2
Display: 04:00:00 ss Sat 01/01/2005
Configure: clock datetime 1:00 2007/1/1, clock timezone
zone-time add 1 and clock summer-time ss one-off 1:00
2008/1/1 1:00 2008/8/8 2
Display: 02:00:00 zone-time Mon 01/01/2007
Configure: clock datetime 1:00 2007/1/1, clock timezone
zone-time add 1 and clock summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
Display: 04:00:00 ss Mon 01/01/2007
Configure: clock timezone zone-time add 1, clock
summer-time ss one-off 1:00 2008/1/1 1:00 2008/8/8 2
and clock datetime 1:00 2007/1/1
Display: 01:00:00 zone-time Mon 01/01/2007
Configure: clock timezone zone-time add 1, clock
summer-time ss one-off 1:00 2008/1/1 1:00 2008/8/8 2
and clock datetime 1:30 2008/1/1
Display: 23:30:00 zone-time Mon 12/31/2007
Configure: clock timezone zone-time add 1, clock
summer-time ss one-off 1:00 2008/1/1 1:00 2008/8/8 2
and clock datetime 3:00 2008/1/1
Display: 03:00:00 ss Tue 01/01/2008