Power Over Ethernet
Displaying System PoE Status
To display the PoE status for the switch, use the following command:
show inline-power
The command provides status for the following areas:
Configured inline power status—The status of the inline power for the switch: enabled or disabled.
System power surplus—The surplus amount of power on the system, in watts, available for
budgeting.
Redundant power surplus—The amount of power on the system, in watts, available for budgeting if
one power supply is lost.
System power usage threshold—The configured power usage threshold for each slot, shown as a
percentage of budgeted power. Once this threshold has been passed on any slot, the system sends an
SNMP event and logs a message.
Disconnect precedence—The method of denying power to PDs if the budgeted power on any slot is
exceeded.
Legacy mode—The status of the legacy mode, which allows detection of non-standard PDs.
The output indicates the following inline power status information for each slot:
Inline power status—The status of inline power. The status conditions are:
Enabled
Disabled
Firmware status—The operational status of the slot. The status conditions are:
Operational
Not operational
Disabled
Subsystem failure
Card not present
Slot disabled
Budgeted power—The amount of inline power, in watts, that is reserved and available to the slot.
Measured power—The amount of power, in watts, that is currently being used by the slot.
Following is sample output from this command:
Configured
System Power Surplus
Redundant Power Surplus
Power Usage Threshold
Disconnect Precedence
Legacy Mode
Slot
Inline-Power
3
Enabled
4
Enabled
7
Enabled
Note: A budget value in parentheses is not allocated from the system power
budget because the card is not present, or the slot is disabled.
174
Inline Power System Information
: Enabled
: 1500 Watts available for budgeting
:
465 Watts available for budgeting to maintain N+1
: 70 percent (per slot)
: lowest-priority
: Disabled
Firmware Status
Operational
Card Not Present
Operational
Budgeted
Measured
Power (Watts)
Power (Watts)
50 W
9 W
( 50 W)
n/a
50 W
0 W
ExtremeWare XOS 11.3 Concepts Guide