Technical Specifications - Paradyne COMSPHERE 3610 User Manual

Data service units
Hide thumbs Also See for COMSPHERE 3610:
Table of Contents

Advertisement

Technical Specifications

Technical Specifications
The 3600 Series DSUs can be used as a Local Area
Data Set (LADS) to provide a point-to-point link between
two devices. The network facility is a direct 4-wire
crossover connection without using a digital service.
Tables F-1 through F-6 list the technical specifications
for the following:
Data Rate
(kbps)
2.4
4.8
9.6
19.2*
38.4
56
64
* Power level is –10 dBm.
3610-A2-GB46-60
Technical Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table F-1
LADS Connection Distances for
Models 3610 - A3-xxx and 3611-A3-xxx or Lower
Wire Diameter (AWG)
19 Gauge
22 Gauge
(.0359 or
(.0253 or
.9122 mm)
.643 mm)
20.0 mi
16.6 mi
(32.2 km)
(26.7 km)
19.4 mi
12.7 mi
(31.2 km)
(20.5 km)
15.2 mi
9.7 mi
(24.5 km)
(15.6 km)
11.8 mi
7.5 mi
(19.0 km)
(12.1 km)
11.2 mi
6.5 mi
(18.0 km)
(10.5 km)
9.2 mi
5.4 mi
(14.8 km)
(8.7 km)
9.2 mi
5.4 mi
(14.8 km)
(8.7 km)
December 1996
LADS maximum connection distance requirements
(Tables F-1 and F-2)
3600 Series DSU (Tables F-3 and F-4)
3600 Hubbing Device for use with a Model 3610
DSU only (Table F-5)
Async Terminal for use with a Model 3610 DSU
only (Table F-6)
24 Gauge
26 Gauge
(.0201 or
(.0159 or
.511 mm)
.404 mm)
12.7 mi
9.4 mi
(20.5 km)
(15.1 km)
9.6 mi
7.1 mi
(15.4 km)
(11.5 km)
7.3 mi
5.6 mi
(11.7 km)
(9.0 km)
5.7 mi
4.2 mi
(9.2 km)
(6.8 km)
4.6 mi
3.2 mi
(7.4 km)
(5.1 km)
3.8 mi
2.8 mi
6.2 km)
(4.5 km)
3.8 mi
2.8 mi
(6.2 km)
(4.5 km)
F
F-1
F-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3611Comsphere 3600 series

Table of Contents