Audible Beeps: None
Possible Cause: The primary system ROM is corrupt. The system is booting from the redundant ROM.
Action: Run ROMPaq Utility to restore the system ROM to the correct version.
Temperature violation detected - system Shutting Down in X seconds
Audible Beeps: 1 long, 1 short
Possible Cause: The system has reached a cautionary temperature level and is shutting down in X seconds.
Action: Adjust the ambient temperature, install fans, or replace any failed fans.
There must be a first DIMM in pair if second DIMM in pair is populated. Second
DIMM in pair ignored.
Description: The first DIMM socket in the pair is not populated. The second DIMM in the pair is not
recognized or used.
Action: Populate the DIMM socket.

This DIMM does not support thermal monitoring...

A less efficient cooling solution with fans running at higher speeds will be utilized to allow the system to operate with
this DIMM installed.
Audible Beeps: None
Possible Cause: Unsupported DIMMs are installed that do not contain a temperature sensor. All supported
DIMMs for this platform include internal temperature sensors.
Action: See the server documentation for supported DIMMs. Install only DIMMs supported by the server.
This system only supports 667 MHz Front Side Bus Speed Processors. One or more
800 MHz Front Side Bus Speed Processors have been initialized at 667 MHz.

System Halted!

Audible beeps: 1 long, 1 short
Possible cause: One or more 800-MHz front side bus speed processors have been initialized at 667 MHz.
Action:
CAUTION:
provided in "Performing processor procedures in the troubleshooting process (on page 17)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
Correct the processor configuration.
Unsupported DIMM(s) found in system. - DIMM(s) may not be used
Description: Unsupported memory types found in system.
Action: Refer to the applicable server user guide memory requirements and replace with supported DIMMs.
Before removing or replacing any processors, be sure to follow the guidelines
Error messages 124