Node Interleaving disabled - Invalid memory configuration
Description: Each node must have the same memory configuration to enable interleaving.
Action: Populate each node with the same memory configuration and enable interleaving in RBSU.

No Floppy Drive Present

Audible Beeps: None
Possible Cause: No diskette drive is installed or a diskette drive failure has occurred.
Action:
Power down the server.
1.
Replace a failed diskette drive.
2.
Be sure a diskette drive is cabled properly, if a diskette drive exists.
3.
No Keyboard Present
Audible Beeps: None
Possible Cause: A keyboard is not connected to the server or a keyboard failure has occurred.
Action:
Power down the server, and then reconnect the keyboard.
1.
Be sure no keys are depressed or stuck.
2.
If the failure reoccurs, replace the keyboard.
3.
Parity Check 2 - System DIMM Memory
Audible Beeps: None
Possible Cause: An uncorrectable error memory event occurred in a memory DIMM.
Action: Run Insight Diagnostics
DIMM LEDs to identify failed DIMMs and replace the DIMMs.
PCI Bus Parity Error, PCI Slot X
Audible Beeps: None
Possible Cause: A PCI device has generated a parity error on the PCI bus.
Action: For plug-in PCI cards, remove the card. For embedded PCI devices, run Insight Diagnostics and
replace any failed components as indicated.
Power Fault Detected in Hot-Plug PCI Slot X
Audible Beeps: 2 short
Possible Cause: A PCI-X hot-plug expansion slot was not powered up properly.
Action: Reboot the server.
("HP Insight
Diagnostics" on page 76) to identify failed DIMMs. Then, use the
Error messages 122