Audible Beeps: None
Possible Cause: A drive erase operation was previously initiated by the user and is in progress or is
scheduled for all drives in the list.
Action: None required
1745-Slot X Drive Array - Drive Erase Operation Completed...
...The following disk drive(s) have been erased and will remain offline until hot-replaced or re-enabled by the Array
Configuration Utility:
(followed by a list of drives)
Audible Beeps: None
Possible Cause: The drive erase operation was successfully completed, and the drives are being held in an
offline state to ensure that the drives remain blank until re-enabled by the user.
Action: Replace each drive in the list or re-enable each drive in the list using one of the following methods:
Use the Array Configuration Utility (on page 71) (all drive types).
Perform hot-plug removal and reinstallation (hot-plug hard drives only).
1746-Slot X Drive Array - Unsupported Storage Connection Detected...
...SAS connection via expander is not supported on this controller model. Access to all storage has been disabled.
Upgrade controller or detach the expander based storage connections.
Audible Beeps: None
Possible Cause: The controller or firmware version does not support the attached drive enclosure.
Action: Upgrade the controller, or detach the expander-based storage connections.
1747-Slot X Drive Array - Unsupported Array Configuration Detected...
...Followed by one of many possible reasons, including the following:
*
More logical drives are configured than this controller can support when the memory module is detached.
*
One or more logical drives are configured in positions that this controller does not support when the memory
module is detached.
*
One or more logical drives are configured for RAID fault tolerance level(s) that are not supported when the
memory module is detached.
*
Configuration information indicates one or more hard drives are located in drive bays that are inaccessible when
the memory module is detached.
*
Capacity Expansion operations are pending but cannot continue because the Array Accelerator memory module
has been detached.
*
Drive Erase operations are pending but cannot be completed because the Array Accelerator memory module
has been detached.
ALL logical drives have been disabled. To avoid data loss, re-attach drives to original controller or upgrade controller.
To discard all data and create a new configuration, run the Array Configuration Utility.
Audible Beeps: None
Possible Causes:
The Array Accelerator memory module was removed or is defective.
The drives were moved to a controller that does not have an Array Accelerator memory module
attached.
Error messages 148