Accelerator Status: Obsolete Data Detected
Description: During reset initialization, obsolete data was found in the cache due to the drives being moved
and written to by another controller.
Action: No action is required. The controller either writes the data to the drives or discards the data
completely.
Accelerator Status: Obsolete Data was Discarded
Description: During reset initialization, obsolete data was found in the cache, and was discarded (not written
to the drives).
Action: No action is required.
Accelerator Status: Obsolete Data was Flushed (Written) to Drives
Description: During reset initialization, obsolete data was found in the cache. The obsolete data was written
to the drives, but newer data may have been overwritten.
Action: If newer data was overwritten, you may need to restore newer data; otherwise, normal operation
should continue.
Accelerator Status: Permanently Disabled
Description: Array accelerator board has been permanently disabled. It will remain disabled until it is
reinitialized using ACU.
Action: Check the Disable Code field. Run ACU
array accelerator board.
Accelerator Status: Possible Data Loss in Cache
Description: Possible data loss was detected during power-up due to all batteries being below sufficient
voltage level and no presence of the identification signatures on the array accelerator board.
Action: No way exists to determine if dirty or bad data was in the cache and is now lost.
Accelerator Status: Temporarily Disabled
Description: Array accelerator board has been temporarily disabled.
Action: Check the Disable Code field.
Accelerator Status: Unrecognized Status
Description: A status was returned from the array accelerator board that ADU does not recognize.
Action: Obtain the latest version of ADU
Accelerator Status: Valid Data Found at Reset
Description: Valid data was found in posted-write memory at reinitialization. Data will be flushed to disk.
Action: No error or data loss condition exists. No action is required.
("Array Configuration
("Array diagnostic
software" on page 77).
Utility" on page 71) to reinitialize the