Drive Monitoring Features Are Unobtainable
Description: ADU
due to a fatal command problem (such as drive time-out), or is unable to get data due to these features not
being supported on the controller.
Action: Check for other errors such as time-outs. If no other errors occur, upgrade the firmware to a version
that supports monitor and performance, if desired.
Drive Monitoring is NOT Enabled for SCSI Port X Drive ID Y
Description: The monitor and performance features have not been enabled on this drive.
Action: Run the server setup utility to initialize the monitor and performance features.
Drive Time-Out Occurred on Physical Drive Bay X
Description: ADU issued a command to a physical drive and the command was never acknowledged.
Action: The drive or cable may be bad. Check the other error messages on the Diagnostics screen to
determine resolution.
Drive X Indicates Position Y
Description: Message indicates a designated physical drive, which seems to be scrambled or in a drive bay
other than the one for which it was originally configured.
Action:
Examine the graphical drive representation on ADU
1.
determine proper drive locations.
Power down the server.
2.
Remove drive X and place it in drive position Y.
3.
Rearrange the drives according to the ADU instructions.
4.
Duplicate Write Memory Error
Description: Data cannot be written to the array accelerator board in duplicate due to the detection of parity
errors. This is not a data-loss situation.
Action: Replace the array accelerator board.
Error Occurred Reading RIS Copy from SCSI Port X Drive ID
Description: An error occurred while ADU
RIS from this drive.
Action: HP stores the hard drive configuration information in the RIS. If multiple errors occur, the drive may
need to be replaced.
FYI: Drive (Bay) X is Third-Party Supplied
Description: Third-party supplied the installed drive.
Action: If problems exist with this drive, replace it with a supported drive.
("Array diagnostic
software" on page 77) is unable to get monitor and performance data
("Array diagnostic
("Array diagnostic
software" on page 77) was trying to read the
software" on page 77) to
Error messages 99