Power Supply Solution Not Fully Redundant

Audible beeps: None
Possible cause: The minimum power supply requirement is installed, but a redundant power supply is missing
or failed.
Action: Do one of the following:
Install a power supply.
Replace failed power supplies to complete redundancy.

Processor X Unsupported Wattage.

Audible beeps: 1 long, 1 short
Possible cause: Processor not supported by current server.
Action:
CAUTION:
provided in "Performing processor procedures in the troubleshooting process (on page 17)."
Failure to follow the recommended guidelines can cause damage to the system board, requiring
replacement of the system board.
See the server documentation for supported processors. If the processor is supported, remove the processor,
update the system to latest ROM, and then reinstall the processor.
Redundant ROM Detected - This system contains a valid backup system ROM.
Audible Beeps: None
Possible Cause: The system recognizes both the system ROM and redundant ROM as valid. This is not an
error.
Action: None
REDUNDANT ROM ERROR: Backup ROM Invalid. - ...
...run ROMPAQ to correct error condition.
Audible Beeps: None
Possible Cause: The backup system ROM is corrupted. The primary ROM is valid.
Action: Run ROMPaq Utility to flash the system so that the primary and backup ROMs are valid.
REDUNDANT ROM ERROR: Bootblock Invalid. - ...
...contact HP Representative.
Audible Beeps: None
Possible Cause: ROM bootblock is corrupt.
Action: Contact an authorized service provider.
REDUNDANT ROM ERROR: Primary ROM invalid. Booting Backup ROM. -...
...run ROMPAQ to correct error condition