Fatal Dma Error; Fatal Express Port Error - HP ProLiant DL388 Troubleshooting Manual

Hp proliant servers troubleshooting guide
Hide thumbs Also See for ProLiant DL388:
Table of Contents

Advertisement

Critical Error Occurred Prior to this Power-Up
Audible Beeps: None
Possible Cause: A catastrophic system error, which caused the server to crash, has been logged.
Action: Run Insight Diagnostics
indicated.
Fan Solution Not Fully Redundant
Audible Beeps:
Possible Cause: The minimum number of required fans is installed, but some redundant fans are missing or
failed.
Action: Install fans or replace failed fans to complete redundancy.
Fan Solution Not Sufficient
Audible Beeps:
Possible Cause: The minimum number of required fans is missing or failed.
Action: Install fans or replace any failed fans.

Fatal DMA Error

Audible Beeps: None
Possible Cause: The DMA controller has experienced a critical error that has caused an NMI.
Action: Run Insight Diagnostics
indicated.

Fatal Express Port Error

Audible Beeps: None
Possible Cause: A PCI Express port has experienced a fatal error that caused an NMI.
Action: Run Insight Diagnostics
boards or reseat loose PCI Express boards.
Fatal Front Side Bus Error
Audible Beeps: None
Possible Cause: The processor front-side bus experienced a fatal error.
Action:
Run Insight Diagnostics
1.
CAUTION:
provided in "Performing processor procedures in the troubleshooting process (on page 17)."
Failure to follow the recommended guidelines can cause damage to the system board requiring
replacement of the system board.
("HP Insight
Diagnostics" on page 76) and replace failed components as
("HP Insight
Diagnostics" on page 76) and replace failed components as
("HP Insight
Diagnostics" on page 76) and replace the failed PCI Express
("HP Insight
Diagnostics" on page 76).
Before replacing or reseating any processors, be sure to follow the guidelines
Error messages 118

Advertisement

Table of Contents
loading

Table of Contents