System Board Is Unable To Identify Which Slots The Controllers Are In; The Redundant Controllers Installed Are Not The Same Model - HP ProLiant DL388 Troubleshooting Manual

Hp proliant servers troubleshooting guide
Hide thumbs Also See for ProLiant DL388:
Table of Contents

Advertisement

Description: More logical drives were created than are supported on this controller, causing lost logical drive
volumes.
Action: Identify the drives containing lost volumes, and then move them to another controller so the lost
volumes can be recreated.
CAUTION:

System Board is Unable to Identify which Slots the Controllers are in

Description: The slot indicator on the system board is not working correctly. Firmware recognizes both
controllers as being installed in the same slot.
Action:
Be sure both controllers are fully seated in their slots.
1.
If the problem persists, this might indicate a controller problem or a system board problem.
CAUTION:
board. If you believe the system board requires replacement, contact HP Technical Support
("Contacting
Remove one of the controllers in the configuration and see if the remaining controller generates a POST
2.
message.
Move the remaining controller to the other slot to see if it still generates a POST message.
3.
Repeat these steps with the other controller.
4.
If both controllers give POST messages in one slot but not the other, it is a system board problem. If one of the
controllers gives POST messages and the other controller does not, replace the controller that is giving the
POST messages. Contact an authorized service provider for any warranty replacements.

The Redundant Controllers Installed are not the Same Model...

...SOLUTION: Power down the system and verify that the redundant controllers are different models. If they are different
models, replace the other controller with the same model as this one.
Description: ADU detected two different controller models installed in a redundant controller configuration.
This is not supported and one or both controllers may not be operating properly.
Action: Use the same controller models for redundant controller configurations.
This Controller Can See the Drives but the Other Controller Can't
Description: The other controller in the redundant controller configuration cannot recognize the drives, but
this controller can.
Action: Resolve any other errors and then rerun ADU
This Controller Can't See the Drives but the Other Controller Can
Description: The other controller in the redundant controller configuration can recognize the drives, but this
controller cannot.
Action: Resolve any other errors and then rerun ADU
Removing a drive that contains valid volume data causes all valid data to be lost.
Only authorized technicians trained by HP should attempt to remove the system
HP" on page 177) before proceeding.
("Array diagnostic
software" on page 77).
("Array diagnostic
software" on page 77).
Error messages 109