Management Module Front Panel - 3Com 3C780 - LinkBuilder FDDI Base Unit User Manual

Fddi workgroup hub
Table of Contents

Advertisement

To change the hub's baud rate to match the baud rate of a terminal or modem,
follow these steps:
1.
Enter the set baud command. Type:
set baud
This selection prompt appears:
Select one of the following:
1. 1200
2. 2400
3. 4800
4. 9600
Baudrate?
2.
Type a number to select a baud rate. For example, type:
3 [Enter]
This confirmation appears:
Baud rate changed to 4800
3.
Reset the hub by pressing the recessed RESET button on the

management module front panel.

The new baud rate will take effect when the self-tests are finished.
NOTE: The other default parameters of the serial port are Parity = None, Data
Bits = 8, and Stop Bits = 1.