A-4
System Messages
The xx exponent must be >= the current cutoff exponent
Meaning:
The LER alarm exponent must be greater than the LER cutoff exponent.
Action:
Set the alarm exponent to be greater than the cutoff value.
There are no ports in the management module slot
Meaning:
You entered the slot number 0 (zero) in the show ports command.
Action:
Examine the hub to see where the media modules are installed and enter a
correct slot number.
xx must be in the range xx to xx
Meaning:
An exponent must fall within the given range of values. For example, the LER
Cutoff parameter must be set to a value between 4 to 15.
Action:
Change the value of the exponent to be within the range shown.
Download Messages
Download image requested has invalid format!
Meaning:
You have requested and received the wrong filename. The image that was
downloaded is not an executable image for this filename. You no longer have
an executable image in flash memory.
Action:
Reissue the download request.