Stylus Pro5000
4.2.5.16 Upper Surface Sensor Removal
1. Remove "ASF Unit". (Refer to section 4.2.5.15)
2. Remove the connector (Yellow, 3-pin) located on the "Upper Surface
Sensor".
3. Remove one CBS screw(3x8) securing "Upper Surface Sensor" to "ASF
Unit", and remove "Upper Surface Sensor". (Refer to Figure4-60)
In case of removing or replacing "Upper Surface
Sensor" on the "ASF Unit", refer to Chapter5 and
perform "Upper Surface Positioning Adjustment".
In case of re-installing the upper surface sensor,
CHECK POINT
perform "Upper Surface Positioning
Adjustment", then, apply Neji Lock (screw lock)
to fix the position of tightened screw.
When removing "Upper Surface Sensor" from
"ASF Unit", one spring washer comes off. When
re-assembling them, refer to Figure4-60 and
install this spring washer so that its convex side
should face to the ASF frame, and tighten the
screw.
Rev.B
"Mounting Board Assembly, Upper
Surface Sensor"
CBS(3x8)
Connector(Yellow,3-pin)
"Upper Surface Sensor"
Figure 4-60. Upper Sensor Removal
Chapter4 Assembly and Disassembly
Apply screw lock
after adjustment
is over.
ASF Frame
Spring Washer
(Convex side should
face up)
Sensor Mounting Board
4-32