Epson Stylus Pro 5000 Service Manual page 19

Color ink jet printer
Hide thumbs Also See for Stylus Pro 5000:
Table of Contents

Advertisement

EPSON Stylus Pro 5000
PARALLEL INTERFACE (CONT.)
[ECP Mode]
Table 1-13. ECP Mode
Item
Transmission mode
IEEE-1284 ECP mode
Synchronization
Refer to IEEE-1284 specification
Handshaking
Refer to IEEE-1284 specification
Signal level
TTL level (IEEE-1284 level 1 device)
See forward channel
Adaptable connector
See forward channel
Data transfer timing
Refer to IEEE-1284 specification
Extensibility request data
The printer responds affirmatively when the
extensibility request values are 10H or 14H,
that mean,
10H
14H
The printer sends following device ID string
when it is requested.
Note) [00H] denotes a hexadecimal value of
Rev.A
Content
:Request ECP mode reverse
channel transfer.
:Request device ID; Return Data
using ECP Mode Rev channel
transfer.
[00H]
[3BH]
MFG :
EPSON
CMD :
ESCPL2, BDC
MDL
:
Stylus[SP]Pro[SP]5000
CLS
:
PRINTER
zero. MDL value depends on the
EEPROM setting.
TYPE B OPTIONAL INTERFACE SPECIFICATION
Type-B interface level 2 is supported.
Y
Reply message (Short version):
T
Case of using Co-ax / Twin-ax I/F card:
Main Type:
MTP48p, PW127cl10cpi, PGR(KAxxxx)rev,
AP1200ma
Product Name:
Stylus[SP]Pro[SP]5000
Emulation Type:
ESCPL2-00
Entity Type:
EPSONLQ2
Y
Reply message
T
Case of using except Co-ax / Twin-ax I/F card
Main Type:
MTP48p, PW127cl10cpi, PGR(KAxxx)rev,
AP1200ma, SPD0fast
Product Name:
Stylus[SP]Pro[SP]5000
Emulation Type:
ESCPL2-00
Entity Type:
ESPONLQ2
BUFFER OPERATION
Stylus Pro5000 starts sending BUSY signal when it acknowledges no
available area left in the buffer. When the host keeps receiving this signal
for a long time, it acknowledges as time out and stops sending data.
INTERFACE SELECTION
The printer has 3-built in interfaces; the parallel interface and serial
interface, and has 1 optional Type-B interface card slot. These interfaces
are selected manually by the default setting mode or selected automatically.
(However, it is necessary to set these settings within the maintenance mode
level 1 of the panel operation.)
T
Manual Selection:
One of three interfaces can be selected by the default setting mode.
Chapter1 Product Description