Checking The Effectiveness Of Delay Announcements - Lucent Technologies MERLIN LEGEND 6 System Manager's Manual

Communications system
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.0
System Manager's Guide 555-660-118
8
Troubleshooting the System
Secondary Announcements Not Playing as Programmed
Consult the Feature Reference and System Programming as you
troubleshoot announcement delays.
To analyze a problem with secondary announcements, follow these preliminary
steps:
1.
The Calls In Queue Alarm Threshold setting should determine when an
alarm is signalled. Set the overflow threshold time to 0.
2.
Set up primary and secondary announcements of durations that seem
appropriate for your needs.
3.
Specify a reasonable announcement interval (for example, 30 seconds).
4.
Refer to Table 8-1 and divide the announcement interval (Y) by the length
of the secondary announcement (Z).
5.
Round off the result and use this value as an alarm threshold when a
Calls-in-Queue Alarm button signals a problem.
Table 8–1.
Calls Waiting for
Secondary
Announcement
(N)
3
3
5
10
When the number of calls waiting for a secondary announcement multiplied by the
length of that announcement is greater than the announcement interval, an alarm
is triggered.
Alarm button would or would not indicate a problem.
If problems arise, use the display at the calling group supervisor DLC console to
monitor the situation while the problem is most severe. Try to adjust the
announcements' durations and the interval setting so that the announcement
interval is greater than or equal to the length of the secondary announcement
multiplied by the number of calls waiting for the secondary announcement
(Y >= N * Z).
Possible Cause 1: The announcement interval may be too short or the
secondary announcement may be too long.

Checking the Effectiveness of Delay Announcements

Length of
Secondary
Announcement in
Seconds (Z)
10
20
15
15
Table 8–1
illustrates situations where a programmed Calls-in-Queue
Announcement
Interval in
Seconds (Y)
N * Z
30
30
90
90
150
Issue 1
February 1998
Page 8-28
Is N * Z > Y?
30
No
60
Yes
75
No
Yes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merlin legend 6.0

Table of Contents