Replacing A Cooling Fan - Intel SS4200-E - Entry Storage System NAS Server User Manual

Entry storage system
Hide thumbs Also See for SS4200-E - Entry Storage System NAS Server:
Table of Contents

Advertisement

Hardware Installations and Upgrades

Replacing a Cooling Fan

Warning: Removal of a cooling fan must only be performed by a qualified service person. Potential
hazards include:
— Energy hazard
— Hot surfaces
— Access to power supply openings
Caution: Before performing any maintenance on the system, back up the data. Follow the
instructions in the operating system manual or third-party software documentation for
shutting down the system.
Warning: Upon completion of cooling fan replacement, the enclosure cover MUST be properly re-
installed to ensure adequate cooling of the system.
1. Check the new fan for damage. Do not install it if there are any visible signs of
damage. Return to vendor for replacement.
2. Observe all safety and ESD precautions listed in
3. Turn off all peripheral devices connected to the storage system. Power down the
storage system.
4. Disconnect the AC power cord.
5. Remove the enclosure cover. For instructions, see
on page
32
20.
"Safety Information" on page
"Removing the Enclosure Cover"
Intel® Entry Storage System SS4200-E User Guide
85.